184 research outputs found

    Electromigration early resistance increase measurements

    Get PDF
    An early resistance change measurement set-up, using an AC bridge technique, has been developed, and measurements have been performed. Large sample-to-sample variations occur. The characteristic time for the resistance change curve is shorter for resistance increase (under current stress) than for resistance decay (during recovery)

    An empirical model for early resistance changes due to electromigration

    Get PDF
    A new heuristic description for electromigration-induced early resistance changes is given. The basis is formed by two coupled partial differential equations, one for vacancies, and one for imperfections. These equations are solved numerically for a grain boundary bamboo structure. It is shown that this model is capable of simulating the typical effects as observed in early resistance change measurements. These early resistance changes are due to the redistributions of the vacancies and the generation of imperfections. Simulations are performed that closely match the measured resistance change curves

    A test chip for automatic reliability measurements of interconnect vias

    Get PDF
    A test circuit for electromigration reliability measurements was designed and tested. The device under test (DUT) is a via-hole chain. The test circuit permits simultaneous measurements of a number of DUTs, and a fatal error of one DUT does not influence the measurement results of the other DUTs. Measurements require only a few measurement instruments. Comparing the measurement results of a single DUT io the measurement results of the test circuit shows that the test circuit may be used for reliability measurements

    Robust and Efficient Uncertainty Quantification and Validation of RFIC Isolation

    Get PDF
    Modern communication and identification products impose demanding constraints on reliability of components. Due to this statistical constraints more and more enter optimization formulations of electronic products. Yield constraints often require efficient sampling techniques to obtain uncertainty quantification also at the tails of the distributions. These sampling techniques should outperform standard Monte Carlo techniques, since these latter ones are normally not efficient enough to deal with tail probabilities. One such a technique, Importance Sampling, has successfully been applied to optimize Static Random Access Memories (SRAMs) while guaranteeing very small failure probabilities, even going beyond 6-sigma variations of parameters involved. Apart from this, emerging uncertainty quantifications techniques offer expansions of the solution that serve as a response surface facility when doing statistics and optimization. To efficiently derive the coefficients in the expansions one either has to solve a large number of problems or a huge combined problem. Here parameterized Model Order Reduction (MOR) techniques can be used to reduce the work load. To also reduce the amount of parameters we identify those that only affect the variance in a minor way. These parameters can simply be set to a fixed value. The remaining parameters can be viewed as dominant. Preservation of the variation also allows to make statements about the approximation accuracy obtained by the parameter-reduced problem. This is illustrated on an RLC circuit. Additionally, the MOR technique used should not affect the variance significantly. Finally we consider a methodology for reliable RFIC isolation using floor-plan modeling and isolation grounding. Simulations show good comparison with measurements

    Simulations of inner magnetosphere dynamics with an expanded RAM-SCB model and comparisons with Van Allen Probes observations

    Get PDF
    Abstract Simulations from our newly expanded ring current-atmosphere interactions model with self-consistent magnetic field (RAM-SCB), now valid out to 9 R E, are compared for the first time with Van Allen Probes observations. The expanded model reproduces the storm time ring current buildup due to the increased convection and inflow of plasma from the magnetotail. It matches Magnetic Electron Ion Spectrometer (MagEIS) observations of the trapped high-energy (\u3e50 keV) ion flux; however, it underestimates the low-energy (\u3c10 keV) Helium, Oxygen, Proton, and Electron (HOPE) observations. The dispersed injections of ring current ions observed with the Energetic particle, Composition, and Thermal plasma (ECT) suite at high (\u3e20 keV) energy are better reproduced using a high-resolution convection model. In agreement with Electric and Magnetic Field Instrument Suite and Integrated Science (EMFISIS) observations, RAM-SCB indicates that the large-scale magnetic field is depressed as close as ∼4.5 RE during even a moderate storm. Regions of electromagnetic ion cyclotron instability are predicted on the duskside from ∼6 to ∼9 RE, indicating that previous studies confined to geosynchronous orbit may have underestimated their scattering effect on the energetic particles. Key Points Expanded RAM-SCB model reproduces well high-energy (\u3e50 keV) MagEIS observations The magnetic field is depressed as close as ∼4.5 RE during even a moderate storm EMIC wave growth extends on duskside from ∼6 to ∼9 RE during storm main phase

    Six Years Follow-up of the Levels of TNF-α and IL-6 in Patients with Complex Regional Pain Syndrome Type 1

    Get PDF
    In an earlier study, levels of the proinflammatory cytokines TNF-α and IL-6 are higher in blisters fluid from the complex regional pain syndrome type 1 (CRPS1) side obtained at 6 and 30 months (median) after the initial event. The aim of this follow-up study is to determine the involvement of these cytokines in long lasting CRPS1. Twelve CRPS1 patients, with median disease duration of 72 months, participated. The levels of TNF-α and IL-6 were measured in blister fluid; disease activity was reevaluated by measuring pain and differences in temperature, volume, and mobility between both extremities. Differences in levels of IL-6 and TNF-α and mobility between both sides were significantly decreased. Pain and differences in temperature and volume were not significantly altered. No correlation was found between the cytokines and the disease characteristics. These results indicate that IL-6 and TNF-α are only partially responsible for the signs and symptoms of CRPS1

    Postural change in volunteers: sympathetic tone determines microvascular response to cardiac preload and output increases

    Get PDF
    Purpose: Microvascular perfusion may be a non-invasive indicator of fluid responsiveness. We aimed to investigate which of the microvascular perfusion parameters truly reflects fluid responsiveness independent of sympathetic reflexes. Methods: Fifteen healthy volunteers underwent a postural change from head up tilt (HUT) to the supine position, diminishing sympathetic tone, followed by a 30° passive leg raising (PLR) with unaltered tone. Prior to and after the postural changes, stroke volume (SV) and cardiac output (CO) were measured, as well as sublingual microcirculatory perfusion (sidestream dark field imaging), skin perfusion, and oxygenation (laser Doppler flowmetry and reflectance spectroscopy). Results: In responders (subjects with >10 % increase in CO), the HUT to supine change increased CO, SV, and pulse pressure, while heart rate, systemic vascular resistance, and mean arterial pressure decreased. Additionally, microvascular flow index, laser Doppler flow, and microvascular hemoglobin oxygen saturation and concentration also increased. Conclusion: When preload and forward flow increase in association with a decrease in sympathetic activity, microvascular blood flow increases in the skin and in the sublingual area. When preload and forward flow increase with little to no change in sympathetic activity, only sublingual functional capillary density increases. Therefore, our results indicate that sublingual functional capillary density is the best pa

    Comparison between pulse wave velocities measured using Complior and measured using Biopac

    Get PDF
    Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed around the neck and the wrist. The Biopac system is an easier to use alternative that uses ECG and simple optical sensors to measure the PWV between the heart and the fingertips, and thus extends a bit more to the peripheral vasculature compared to the Complior system. The goal of this study was to test under various conditions to what extent these systems provide comparable and correlating values. 25 Healthy volunteers, 20–30 years old, were measured in four sequential position: sitting, lying, standing and sitting. The results showed that the Biopac system measured consistently and significantly lower PWV values than the Complior system, for all positions. Correlation values and Bland–Altman plots showed that despite the difference in PWV magnitudes obtained by the two systems the measurements did agree well. Which implies that as long as the differences in PWV magnitudes are taken into account, either system could be used to measure PWV changes over time. However, when basing diagnosis on absolute PWV values, one should be very much aware of how the PWV was measured and with what system
    corecore